Dairy Processor Directory

Processing Basics

How to Read a Pasteurizer Chart Recorder

To read a pasteurizer chart, ask one question: did the temperature trace stay at or above the legal pasteurization line whenever milk was moving forward? If yes all day, the chart is boring, which is the goal. If the trace dips, check whether the flow diversion device did its job and whether anyone wrote down what happened.

An inspector will ask the same things.

What is on the chart

Most HTST systems use a circular chart that turns once every 12 or 24 hours while a pen traces temperature at the end of the holding tube. Details vary, but expect:

  • Temperature scale: concentric rings, with the pasteurization temperature for the product identified.
  • Time scale: hours that must match the real time.
  • Pen trace: the recorded temperature.
  • Diversion marks: a separate pen or part of the trace showing forward flow or divert.
  • Operator notes: product, date, initials, start and stop events, tests and remarks.

Time and temperature come from the Pasteurized Milk Ordinance and your state rules. For ordinary milk, HTST is commonly 161F for at least 15 seconds, with higher temperatures for products with more fat or added sweeteners. Use the line marked on your chart and your written procedure rather than assuming.

Reading a normal day

  1. Find startup. The trace climbs as the system heats.
  2. Find the forward-flow window. Once at temperature and in forward flow, the trace should sit at or above the legal line.
  3. Check steadiness. A small regular wiggle is normal. A trace that hugs the line and keeps cutting below it signals a controller problem.
  4. Find shutdown, where the trace falls during rinse or cleaning.
  5. Verify the notes are complete.

Diversion versus deviation

A diversion happens when temperature at the end of the holding tube falls below the cut-out setting while milk flows forward. The device sends milk back to the balance tank or a reprocess route. On the chart you see a dip with a mark showing the valve moved to divert, and forward flow resumes only after the temperature recovers to the cut-in setting.

A diversion is the safety system working. Ask:

  • Did the valve actually divert, and do chart and device agree?
  • Was the diverted milk reprocessed per your plan and not packaged?
  • Why did the temperature drop? Causes include steam supply, a stuck control valve, a flow change or a heat exchanger problem.

A deviation is serious: milk flowed forward below the legal temperature, or the diversion did not move. Warning signs are a dip with no diversion mark, or a trace flat at one exact value for hours, which may mean a stuck pen. Do not hope it away. Stop and hold product, tell your food safety lead and follow your written procedure. Release depends on your food safety program and, where required, the regulator. Practice the response through a mock recall.

Common chart problems

What you seeWhat it may mean
Flat or motionless traceStuck pen, dry ink, jammed chart or sensor fault
Trace above the indicating thermometerRecorder needs checking by the right person
Trace hovering at the lineSet point too close to the minimum, or poor control
Missing notes or initialsRecord gap that inspectors treat as a problem

Habits that keep charts honest

  • Compare the recorder with the indicating thermometer at the intervals your plan requires.
  • Write notes as events happen, not at the end of the week.
  • Keep charts for the retention period your regulator requires.

Charts are one part of equipment checks. See preventive maintenance for pasteurizers and pumps, signs a plate heat exchanger needs service and HTST vs vat pasteurization. For official requirements, start with your state dairy regulator, FDA's food program pages and the Wisconsin Center for Dairy Research.

Quick answers

What temperature should an HTST chart show?

For standard milk it is commonly 161F or above at the end of the holding tube, higher for some products. Use the value in your regulator's rules and your written procedure.

What does a flow diversion look like on a chart?

Usually a dip in the temperature trace paired with a mark showing the valve moved to divert. It should return to forward flow only after temperature recovers to the cut-in setting.

How long do plants keep pasteurizer charts?

Your regulator and food safety plan set the period, commonly measured in months. Ask your state dairy inspector for the exact requirement.

Sources and further reading

Reviewed 2026-11-23. Educational only; follow your milk buyer, regulator and veterinarian for rules that apply to your farm.

More from farm.FM Need a break from the paperwork? Farm humor and funny farm stories are always in season at farm.FM.